Rain Sheds
heat-shrinkable-rain-sheds-incompatible.json
{
"url": "https://axis-india.com/heat-shrinkable-rain-sheds/",
"type": "elementor_product",
"main_heading": "Rain Sheds",
"title": "Rain Sheds",
"description": "Rain sheds enhance insulation on high-voltage cable terminations by increasing creepage distance and preventing flashovers. Moreover, they resist UV exposure and seal tightly using heat-shrinkable polymer. As a result, they perform reliably in harsh, polluted, and coastal environments. Rain sheds are ideal for use in substations, transformers, and outdoor switchgear. Additionally, their design ensures stable operation with minimal maintenance.",
"tabs": {
"Technical Data": "<div aria-labelledby=\"pp-advanced-tabs-title-8621\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content pp-tab-active\" data-index=\"8621\" data-tab=\"1\" id=\"pp-advanced-tabs-content-8621\" role=\"tabpanel\">\n<p> </p><p><style>\n<p>table {<br /> width: 100%;<br />}</p>\n<p>td {<br /> text-align: center ;<br />}<br /></style></p><table style=\"width: 100%;\"><tbody><tr><th>Property</th><th>Test Method</th><th>Standard Value</th></tr><tr><td>Tensile Strength</td><td>ASTM-D-638</td><td>≥8MPa</td></tr><tr><td>Elongation at Break</td><td>ASTM-D-638</td><td>≥300%</td></tr><tr><td>Tensile Strength Variation After Heat Aging(130℃x168h)</td><td>ASTM-D-5510</td><td>≤±30%</td></tr><tr><td>Elongation at Break Variation After Heat Aging(130℃x168h)</td><td>ASTM-D-5510</td><td>≤±30%</td></tr><tr><td>Volume Resistivity</td><td>IEC 60093</td><td>≥1×1014Ω.cm</td></tr><tr><td>Dielectric Strength</td><td>IEC 60243</td><td>≥20kV/mm</td></tr><tr><td>Brittle Temperature</td><td>ISO 974</td><td>-40℃</td></tr><tr><td>Tracking Strength</td><td>IEC 60587</td><td>1A3.5</td></tr><tr><td>Dielectric Constant</td><td>IEC 60250</td><td>≤5</td></tr><tr><td>Heat Shock</td><td>160℃,4h</td><td>No Crack</td></tr><tr><td>Water Absorption(23±2)℃ 24h</td><td>ISO 62</td><td>≤0.1%</td></tr><tr><td>Hardness(Shore A)</td><td>ISO 868</td><td>≥80</td></tr></tbody></table> </div>",
"Dimensions": "<div aria-labelledby=\"pp-advanced-tabs-title-8622\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8622\" data-tab=\"2\" id=\"pp-advanced-tabs-content-8622\" role=\"tabpanel\">\n<p> </p><p><style>\ntable {<br /> width: 100%;<br />}</p>\n<p>td {<br /> text-align: center ;<br />}<br /></style></p><table style=\"width: 100%;\"><tbody><tr><th rowspan=\"2\">D/mm(±5)</th><th colspan=\"1\">As Supplied(mm)</th><th colspan=\"2\">After Recovered</th></tr><tr><th>Inner Diameter (d) (±5)</th><th>Inner Diameter (d) Max</th><th>Wall Thickness (W) (±0.4)</th></tr><tr><td>90</td><td>30</td><td>12</td><td>2.8</td></tr><tr><td>90</td><td>35</td><td>12</td><td>2.8</td></tr><tr><td>120</td><td>40</td><td>20</td><td>2.8</td></tr><tr><td>120</td><td>45</td><td>20</td><td>2.8</td></tr><tr><td>120</td><td>50</td><td>20</td><td>2.8</td></tr><tr><td>120</td><td>55</td><td>20</td><td>2.8</td></tr><tr><td>120</td><td>60</td><td>20</td><td>2.8</td></tr><tr><td>140</td><td>75</td><td>30</td><td>2.6</td></tr><tr><td>140</td><td>80</td><td>30</td><td>2.6</td></tr></tbody></table> </div>",
"1x": "<div aria-labelledby=\"pp-advanced-tabs-title-8623\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8623\" data-tab=\"3\" id=\"pp-advanced-tabs-content-8623\" role=\"tabpanel\">\n<p> </p><p><style>\ntable {<br /> width: 100%;<br />}</p>\n<p>td {<br /> text-align: center ;<br />}<br /></style></p><table style=\"width: 100%;\"><tbody><tr><th rowspan=\"2\">Spec.</th><th colspan=\"2\">As Supplied(mm)</th><th colspan=\"2\">After Recovered</th></tr><tr><th>Inner Diameter (d) (±5)</th><th>Wall Thickness (T) (±20%)</th><th>Inner Diameter (D) Max</th><th>Wall Thickness (T) (±10%)</th></tr><tr><td>WRSSQ-35/17</td><td>35</td><td>1.9</td><td>17</td><td>2.8</td></tr><tr><td>WRSSQ-40/24</td><td>40</td><td>1.9</td><td>24</td><td>2.8</td></tr><tr><td>WRSSQ-50/24</td><td>50</td><td>1.9</td><td>24</td><td>2.8</td></tr><tr><td>WRSSQ-60/32</td><td>60</td><td>2.4</td><td>32</td><td>2.8</td></tr><tr><td>WRSSQ-70/32</td><td>70</td><td>2.4</td><td>32</td><td>2.8</td></tr></tbody></table> </div>",
"3x": "<div aria-labelledby=\"pp-advanced-tabs-title-8624\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8624\" data-tab=\"4\" id=\"pp-advanced-tabs-content-8624\" role=\"tabpanel\">\n<p> </p><p><style>\ntable {<br /> width: 100%;<br />}</p>\n<p>td {<br /> text-align: center ;<br />}<br /></style></p><table style=\"width: 100%;\"><tbody><tr><th rowspan=\"2\">Spec.</th><th colspan=\"2\">As Supplied(mm)</th><th colspan=\"2\">After Recovered</th></tr><tr><th>Inner Diameter (d) (±5)</th><th>Wall Thickness (T) (±20%)</th><th>Inner Diameter (D) Max</th><th>Wall Thickness (T) (±10%)</th></tr><tr><td>WRSSQ-35/16</td><td>35</td><td>1.1</td><td>16</td><td>2.7</td></tr><tr><td>WRSSQ-45/22</td><td>40</td><td>1.1</td><td>22</td><td>3</td></tr><tr><td>WRSSQ-50/22</td><td>50</td><td>1.1</td><td>22</td><td>3</td></tr></tbody></table> </div>",
"Features": "<div aria-labelledby=\"pp-advanced-tabs-title-8625\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8625\" data-tab=\"5\" id=\"pp-advanced-tabs-content-8625\" role=\"tabpanel\">\n<p>Rain Sheds are essential in high-voltage power systems, enhancing insulation by increasing creepage distance to prevent tracking and flashovers in harsh environments. Made from durable, UV-resistant polymeric materials, they repel moisture and contaminants to maintain system reliability. Easy to install with a heat-shrinkable design and optional mastic lining, Rain Sheds are ideal for substations, transformers, and outdoor switchgear in polluted or coastal areas.</p><p><strong>Features</strong> –</p><ol><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Increases Creepage Distance: Enhances insulation performance by extending the creepage path, reducing the risk of electrical tracking and flashovers.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Weather and UV Resistant: Designed to withstand extreme environmental conditions, including prolonged exposure to sunlight, rain, and temperature variations.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Anti-Tracking Properties: Prevents electrical tracking and leakage currents, ensuring long-term insulation stability.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Water-Resistant Mastic Coating: Provides additional protection against moisture ingress, ensuring a strong and secure bond with the cable insulation.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Heat-Shrinkable Design: Allows for quick and easy installation, conforming securely to the cable surface for a tight fit.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Shrink Ratio: Typically 2:1 or 3:1, allowing flexibility to accommodate different cable sizes and diameters.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">High-Temperature Resistance: Can withstand extreme weather conditions and requires a minimum recovery temperature of approximately 120°C for proper installation.</span></li><li aria-level=\"1\" style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Versatile Application: Ideal for use in power cable terminations for substations, overhead lines, transformers, and outdoor switchgear.</span></li></ol> </div>"
},
"images": [
"https://axis-india.com/wp-content/uploads/2024/12/2-6.webp"
]
}