Anti Tracking Tube
anti-tracking-tube-axis-electricals-incompatible.json
{
"url": "https://axis-india.com/anti-tracking-tube-axis-electricals/",
"type": "elementor_product",
"main_heading": "Anti Tracking Tube",
"title": "Anti Tracking Tube",
"description": "Axis Anti Tracking Tube is a high-performance insulation solution for medium-voltage (MV) applications. Made from radiation crosslinked polyolefins, it provides exceptional electrical insulation, tracking resistance, and mechanical protection for cable joints and terminations. Its advanced anti-tracking properties prevent electrical discharge, surface erosion, and insulation failure in harsh environments, such as humid or coastal conditions. With a 3:1 heat shrink ratio and adhesive inner layer, it forms a secure, water-resistant seal, ensuring long-term reliability and environmental protection. Ideal for MV heat shrink terminations and jointing kits, the Axis Anti Tracking Tube is designed for critical electrical infrastructure.",
"tabs": {
"Technical Data": "<div aria-labelledby=\"pp-advanced-tabs-title-8621\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content pp-tab-active\" data-index=\"8621\" data-tab=\"1\" id=\"pp-advanced-tabs-content-8621\" role=\"tabpanel\">\n<p> </p><p><style>\ntable, td, th {<br />td {<br />text-align: center;<br />}<br /></style></p><table style=\"width: 100%;\"><tbody><tr><th>Property</th><th>Test Method</th><th>Standard Value</th></tr><tr><td>Tensile Strength(MPa)</td><td>ASTM-D-638</td><td>≥8MPa</td></tr><tr><td>Elongation at Break</td><td>ASTM-D-638</td><td>≥300%</td></tr><tr><td>Tensile Strength Variation After Heat Aging(130℃x168h)</td><td>ASTM-D-5510</td><td>≤±30%</td></tr><tr><td>Elongation at Break Variation After Heat Aging(130℃x168h)</td><td>ASTM-D-5510</td><td>≤±30%</td></tr><tr><td>Volume resistivity</td><td>IEC 60243</td><td>≥1×1014Ω.cm</td></tr><tr><td>Dieletric strength</td><td>IEC 60243</td><td>≥20kV/mm</td></tr><tr><td>Tracking Resistance</td><td>IEC 60587</td><td>1A 3.5</td></tr><tr><td>Dielectric Constant</td><td>IEC 60250</td><td>≤5</td></tr><tr><td>Heat Shock</td><td>160℃,4h</td><td>No Crack</td></tr><tr><td>Water Absorption (23±2)℃ 24h</td><td>ISO 62</td><td>≤0.1%</td></tr><tr><td>Hardness(Shore A)</td><td>ISO 868</td><td>≥80</td></tr><tr><td>Brittle Temperature</td><td>ISO 974</td><td>-40℃</td></tr></tbody></table> </div>",
"Technical Table": "<div aria-labelledby=\"pp-advanced-tabs-title-8622\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8622\" data-tab=\"2\" id=\"pp-advanced-tabs-content-8622\" role=\"tabpanel\">\n\t\t\t\t\t\t\t \n\n<style>\ntable, td, th {<br />td {<br />text-align: center;<br />}<br /></style>\n\nInner Diameter minWall Thickness (±0.3)Inner Diameter maxWall Thickness (±0.3)\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<th colspan=\"2\">As Supplied/mm</th>\n<th colspan=\"2\">After Recovered/mm</th>\n<th colspan=\"1\">Standard Cut Length /mm</th>\n<th colspan=\"2\">Standard Continous Length(m/roll)</th>\n</tr>\n<tr>\n<td>30</td>\n<td>1</td>\n<td>12</td>\n<td>2.2</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>35</td>\n<td>1</td>\n<td>14</td>\n<td>2.3</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>40</td>\n<td>1</td>\n<td>17</td>\n<td>2.3</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>50</td>\n<td>1</td>\n<td>22</td>\n<td>2.5</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>35</td>\n<td>1.2</td>\n<td>13</td>\n<td>3</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>40</td>\n<td>1.2</td>\n<td>15</td>\n<td>3</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>50</td>\n<td>1.1</td>\n<td>19</td>\n<td>3</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>55</td>\n<td>1.4</td>\n<td>24</td>\n<td>3.2</td>\n<td>600-1200</td>\n<td>25</td>\n</tr>\n<tr>\n<td>60</td>\n<td>1.4</td>\n<td>26</td>\n<td>3.2</td>\n<td>600-1200</td>\n<td>15</td>\n</tr>\n<tr>\n<td>70</td>\n<td>1.4</td>\n<td>29</td>\n<td>3.2</td>\n<td>600-1200</td>\n<td>15</td>\n</tr>\n<tr>\n<td>75</td>\n<td>1.5</td>\n<td>35</td>\n<td>3.2</td>\n<td>600-1200</td>\n<td>15</td>\n</tr>\n<tr>\n<td>80</td>\n<td>1.4</td>\n<td>36</td>\n<td>3.2</td>\n<td>600-1200</td>\n<td>15</td>\n</tr>\n<tr>\n<td>90</td>\n<td>1.6</td>\n<td>45</td>\n<td>3.5</td>\n<td>600-1200</td>\n<td>15</td>\n</tr>\n<tr>\n<td>100</td>\n<td>1.5</td>\n<td>45</td>\n<td>3.5</td>\n<td>600-1200</td>\n<td>15</td>\n</tr>\n</tbody>\n</table> </div>",
"Features": "<div aria-labelledby=\"pp-advanced-tabs-title-8623\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8623\" data-tab=\"3\" id=\"pp-advanced-tabs-content-8623\" role=\"tabpanel\">\n<p>Axis Anti Tracking Tube is designed for medium-voltage applications, offering superior insulation, tracking resistance, and protection for cable joints and terminations. Made from radiation crosslinked polyolefins with a 3:1 heat shrink ratio and adhesive lining, it forms a tight, moisture-resistant seal. The Anti Tracking Tube performs reliably in harsh, humid, and polluted environments, making it ideal for MV terminations and joints where long-term durability and electrical performance are critical.</p><h5>Features –</h5><ol><li><p>Adhesive-Coated Inner Layer: Bonds securely to cable surfaces, enhancing moisture resistance.</p></li><li><p>3:1 Shrink Ratio: Adapts easily to a variety of cable diameters for a tight, flexible fit.</p></li><li><p>Full Recovery Temperature – 130°C: Ensures proper shrinkage and sealing performance.</p></li><li><p>Superior Anti-Tracking Performance: Minimizes leakage and electrical tracking over long service life.</p></li><li><p>Excellent Erosion Resistance: Withstands both electrical and environmental stress.</p></li><li><p>Halogen-Free & Flame Retardant: Reduces fire risk and limits toxic emissions during combustion.</p></li><li><p>UV & Weather Resistant: Protects against sun, rain, and fluctuating outdoor conditions.</p></li><li><p>Chemical & Corrosion Resistant: Provides strong protection from industrial chemicals and pollutants.</p></li><li><p>Strong Mechanical Protection: Shields cables from abrasion, impact, and mechanical wear.</p></li><li><p>Heat-Shrinkable & Easy to Install: Forms a uniform, void-free seal when heated.</p></li></ol><h5> </h5><h5>Material –</h5><p>Made from high-quality radiation crosslinked polyolefins for enhanced electrical and mechanical performance.</p><h5> </h5><h5>Application –</h5><p>Widely used in medium-voltage termination and jointing kits, the anti tracking tube provides insulation, environmental sealing, and protection from accidental flashovers in MV systems.</p> </div>"
},
"images": [
"https://axis-india.com/wp-content/uploads/2024/12/1-8.webp"
]
}
anti-tracking-tube-axis-electricals-variants.json
| As Supplied/mm | After Recovered/mm | Standard |
|---|
| Cut Length /mm | Continous Length(m/roll) |
|---|
| 1 | 2.2 | 600-1200 | 25 |
| 1 | 2.3 | 600-1200 | 25 |
| 1 | 2.3 | 600-1200 | 25 |
| 1 | 2.5 | 600-1200 | 25 |
| 1.2 | 3 | 600-1200 | 25 |
| 1.2 | 3 | 600-1200 | 25 |
| 1.1 | 3 | 600-1200 | 25 |
| 1.4 | 3.2 | 600-1200 | 25 |
| 1.4 | 3.2 | 600-1200 | 15 |
| 1.4 | 3.2 | 600-1200 | 15 |
| 1.5 | 3.2 | 600-1200 | 15 |
| 1.4 | 3.2 | 600-1200 | 15 |
| 1.6 | 3.5 | 600-1200 | 15 |
| 1.5 | 3.5 | 600-1200 | 15 |