.. up

Indoor Single Core

heat-shrinkable-kits-indoor-single-core.webp

heat-shrinkable-kits-indoor-single-core-incompatible.json

{
  "url": "https://axis-india.com/heat-shrinkable-kits-indoor-single-core/",
  "type": "elementor_product",
  "main_heading": "Heat Shrinkable Kits (Indoor) - Single Core",
  "title": "Heat Shrinkable Kits (Indoor) - Single Core",
  "description": "The Indoor Single-Core Heat Shrink Termination Kits by Axis are designed to meet the demanding requirements of medium voltage (MV) power cable installations. These Heat Shrink Termination Kits are specifically tailored for three-core, sheathed or armoured cables and are ideal for applications requiring voltages up to 33 kV. Engineered to provide excellent electrical performance, robust mechanical protection, and reliable environmental sealing, these kits ensure the long-term reliability and safe operation of your power systems. Moreover, the kits incorporate high-quality heat shrink technology, which guarantees a secure fit and consistent environmental sealing upon heat application. As a result, these Heat Shrink Termination Kits effectively address critical issues such as partial corona discharge and surface corona, even under challenging operating conditions. Consequently, they help ensure that electrical systems perform optimally and safely over time.",
  "tabs": {
    "Single Core": "<div aria-labelledby=\"pp-advanced-tabs-title-8621\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content pp-tab-active\" data-index=\"8621\" data-tab=\"1\" id=\"pp-advanced-tabs-content-8621\" role=\"tabpanel\">\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<th rowspan=\"2\">Nominal voltage U0/U(Um)</th>\n<th rowspan=\"2\">Cross section (mm2)</th>\n<th colspan=\"2\">Dimensions(mm)</th>\n<th rowspan=\"2\">No. of rain sheds</th>\n</tr>\n<tr>\n<th>L</th>\n<th>D</th>\n</tr>\n<tr>\n<td align=\"center\" rowspan=\"4\">3.6 / 6(7.2)kV</td>\n<td>50-120</td>\n<td rowspan=\"4\">800</td>\n<td rowspan=\"4\">–</td>\n<td rowspan=\"4\">0</td>\n</tr>\n<tr>\n<td>150-240</td>\n</tr>\n<tr>\n<td>300-400</td>\n</tr>\n<tr>\n<td>500</td>\n</tr>\n<tr>\n<td>6 / 10(12)kV</td>\n<td>50 -95</td>\n<td>800</td>\n<td>–</td>\n<td>0</td>\n</tr>\n<tr>\n<td rowspan=\"4\">6.35 / 11(12)kV</td>\n<td>120-185</td>\n<td rowspan=\"4\">800</td>\n<td rowspan=\"4\">–</td>\n<td rowspan=\"4\">0</td>\n</tr>\n<tr>\n<td>240-300</td>\n</tr>\n<tr>\n<td>400-500</td>\n</tr>\n<tr>\n<td>603</td>\n</tr>\n<tr>\n<td rowspan=\"5\">8.7 / 15(17.5)kV</td>\n<td>25-50</td>\n<td rowspan=\"5\">800</td>\n<td rowspan=\"5\">–</td>\n<td rowspan=\"5\">0</td>\n</tr>\n<tr>\n<td>70-120</td>\n</tr>\n<tr>\n<td>150-240</td>\n</tr>\n<tr>\n<td>300-400</td>\n</tr>\n<tr>\n<td>500-630</td>\n</tr>\n<tr>\n<td>12 / 20(24)kV</td>\n<td>35-50</td>\n<td>800</td>\n<td>105</td>\n<td>2</td>\n</tr>\n<tr>\n<td rowspan=\"2\">12.7 / 22(24)kV</td>\n<td>70-120</td>\n<td rowspan=\"2\">800</td>\n<td rowspan=\"2\">105</td>\n<td rowspan=\"2\">2</td>\n</tr>\n<tr>\n<td>150-240</td>\n</tr>\n<tr>\n<td rowspan=\"4\">12.7 / 22(24)kV</td>\n<td>300-400</td>\n<td rowspan=\"4\">800</td>\n<td rowspan=\"4\">140</td>\n<td rowspan=\"4\">2</td>\n</tr>\n<tr>\n<td>500-630</td>\n</tr>\n<tr>\n<td>800-1000</td>\n</tr>\n<tr>\n<td>1200</td>\n</tr>\n<tr>\n<td>18 / 30(36)kV</td>\n<td>35-50</td>\n<td>800</td>\n<td>105</td>\n<td>4</td>\n</tr>\n<tr>\n<td>19 / 33(36)kV</td>\n<td>70-120</td>\n<td>800</td>\n<td>105</td>\n<td>4</td>\n</tr>\n<tr>\n<td rowspan=\"6\">19 / 33(36)kV</td>\n<td>70-120</td>\n<td rowspan=\"6\">800</td>\n<td rowspan=\"6\">140</td>\n<td rowspan=\"6\">4</td>\n</tr>\n<tr>\n<td>150-240</td>\n</tr>\n<tr>\n<td>300-400</td>\n</tr>\n<tr>\n<td>500-630</td>\n</tr>\n<tr>\n<td>800-1000</td>\n</tr>\n<tr>\n<td>1200</td>\n</tr>\n<tr>\n<td>20.8 / 36(42)kV</td>\n<td>50</td>\n<td>800</td>\n<td>140</td>\n<td>4</td>\n</tr>\n<tr>\n<td rowspan=\"6\">26 / 35(42)kV</td>\n<td>70-120</td>\n<td rowspan=\"6\">800</td>\n<td rowspan=\"6\">140</td>\n<td rowspan=\"6\">4</td>\n</tr>\n<tr>\n<td>150-240</td>\n</tr>\n<tr>\n<td>300-400</td>\n</tr>\n<tr>\n<td>500-630</td>\n</tr>\n<tr>\n<td>800-1000</td>\n</tr>\n<tr>\n<td>1200</td>\n</tr>\n</tbody>\n</table> </div>",
    "Description": "<div aria-labelledby=\"pp-advanced-tabs-title-8622\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8622\" data-tab=\"2\" id=\"pp-advanced-tabs-content-8622\" role=\"tabpanel\">\n<p>Axis Indoor Single-Core Termination Kits offer a reliable and efficient solution for medium voltage (MV) cable terminations up to 33 kV. Engineered for performance in enclosed spaces such as panels, control rooms, and indoor substations, these kits support single-core, sheathed or armoured cables with ease.</p><p>The compact design allows smooth installation in space-constrained environments without compromising durability or safety. Axis uses advanced heat shrink materials that shrink tightly upon heating to form a strong, contamination-resistant seal. This barrier effectively blocks moisture and airborne particles, safeguarding the electrical performance of the termination.</p><p>Each kit enhances system reliability through stress control tubing and anti-tracking insulation. These features reduce the risk of electrical discharge and flashover, especially in environments with varying humidity or voltage stress. An adhesive-coated breakout section securely seals the cable crutch, maintaining internal insulation integrity. For simplified earthing, installers can opt for solderless grounding systems that ensure quick and dependable ground connections.</p><p>These kits are compatible with XLPE-insulated cables and support both strippable and removable semi-conductive layers. Their adaptable structure accommodates various cable specifications, making installation more flexible and straightforward.</p><p>With excellent resistance to corrosion and moisture, Axis kits require minimal maintenance over time. They extend the life of cable systems and reduce the likelihood of faults, delivering long-term value. Overall, Axis Indoor Single-Core Termination Kits provide a robust and user-friendly solution for safe and efficient MV terminations in indoor environments.</p> </div>",
    "Features": "<div aria-labelledby=\"pp-advanced-tabs-title-8623\" class=\"pp-advanced-tabs-content elementor-clearfix pp-advanced-tabs-tab_content\" data-index=\"8623\" data-tab=\"3\" id=\"pp-advanced-tabs-content-8623\" role=\"tabpanel\">\n<h5>Features:</h5><p><strong>1. Electrical Stress Control</strong></p><p>Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used in Heat Shrink Termination Kits to smooth out the electrical field at the cable end.</p><p><strong>2. Excellent Anti-tracking Properties</strong></p><p>These Kits include anti-tracking insulation tubes demonstrating excellent tracking and erosion resistance, protecting Axis terminations even in severe service conditions.</p><p><strong>3. Additional Creepage</strong></p><p>Anti-tracking rain sheds in Heat Shrink Termination Kits lengthen surface creepage distance.</p><p><strong>4. Moisture Sealing</strong></p><p>Durable sealing in these kits is achieved by hot-melted adhesive inside the sealing tube and anti-tracking insulation tube. For 3-core cables, the crutch area is sealed and protected with an adhesive-coated breakout installed over the cores and over sheath end.</p><p><strong>5. Earth Connection</strong></p><p>Axis Termination Kits offer either soldering or solderless earth connections to connect metal screen or armour to ground. For cables with wire screens, copper wires are embedded in sealing mastic to prevent corrosion and moisture ingress.</p><p><strong>6. High Mechanical Protection</strong></p><p>Heat shrinkable components in Axis Termination Kits endure abrasion, vibration, and mechanical wear, ensuring cable protection during installation and operation.</p><p><strong>7. Easy Installation</strong></p><p>Heat Shrink Termination Kits feature pre-engineered components that shrink effectively upon heat application, ensuring quick, secure, and efficient installation without additional tools.</p><p><strong>8. Versatile Cable Compatibility</strong></p><p>Heat Shrink Termination Kits seamlessly work with XLPE insulated cables, supporting various semi-conductive layers (removable and strippable), making them adaptable to multiple cable types</p> </div>"
  },
  "images": [
    "https://axis-india.com/wp-content/uploads/2025/02/Untitled-design-1.webp"
  ]
}

heat-shrinkable-kits-indoor-single-core-variants.json

Nominal voltage U0/U(Um)Cross section (mm2)DimensionsNo. of rain sheds
L (mm)D (mm)
3.6 / 6(7.2)kV50-120800–0
3.6 / 6(7.2)kV150-240800–0
3.6 / 6(7.2)kV300-400800–0
3.6 / 6(7.2)kV500800–0
6 / 10(12)kV50 -95800–0
6.35 / 11(12)kV120-185800–0
6.35 / 11(12)kV240-300800–0
6.35 / 11(12)kV400-500800–0
6.35 / 11(12)kV603800–0
8.7 / 15(17.5)kV25-50800–0
8.7 / 15(17.5)kV70-120800–0
8.7 / 15(17.5)kV150-240800–0
8.7 / 15(17.5)kV300-400800–0
8.7 / 15(17.5)kV500-630800–0
12 / 20(24)kV35-508001052
12.7 / 22(24)kV70-1208001052
12.7 / 22(24)kV150-2408001052
12.7 / 22(24)kV300-4008001402
12.7 / 22(24)kV500-6308001402
12.7 / 22(24)kV800-10008001402
12.7 / 22(24)kV12008001402
18 / 30(36)kV35-508001054
19 / 33(36)kV70-1208001054
19 / 33(36)kV70-1208001404
19 / 33(36)kV150-2408001404
19 / 33(36)kV300-4008001404
19 / 33(36)kV500-6308001404
19 / 33(36)kV800-10008001404
19 / 33(36)kV12008001404
20.8 / 36(42)kV508001404
26 / 35(42)kV70-1208001404
26 / 35(42)kV150-2408001404
26 / 35(42)kV300-4008001404
26 / 35(42)kV500-6308001404
26 / 35(42)kV800-10008001404
26 / 35(42)kV12008001404