analog-lightning-strike-counter
✗ no variants.json found for this product
analog-lightning-strike-counter.json
{
"url": "https://axis-india.com/product/analog-lightning-strike-counter/",
"type": "product",
"breadcrumb": "Home > > > Lightning Protection > > > Down Conductors > > Analog Lightning Strike Counter",
"breadcrumb_html": "<nav class=\"woocommerce-breadcrumb\"><a href=\"https://axis.espialsolutions.com/\">Home</a> > <a href=\"https://axis-india.com/product-category/lightning-protection/\">Lightning Protection</a> > <a href=\"https://axis-india.com/product-category/lightning-protection/down-conductors/\">Down Conductors</a> > Analog Lightning Strike Counter</nav>",
"title": "Analog Lightning Strike Counter",
"title_html": "<h2 class=\"product_title entry-title\">Analog Lightning Strike Counter</h2>",
"product_meta": "Code: | N/A",
"product_meta_html": "<div class=\"product_meta\">\n<span class=\"sku_wrapper\">Code: <span class=\"sku\">N/A</span></span>\n</div>",
"variations_html": "<table cellspacing=\"0\" class=\"variations\" role=\"presentation\">\n<tbody>\n<tr>\n<th class=\"label\"><label for=\"pa_counter-size\">Counter Size</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_pa_counter-size\" data-show_option_none=\"yes\" id=\"pa_counter-size\" name=\"attribute_pa_counter-size\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"120-x-80-x-60-mm\">120 x 80 x 60 mm</option></select><ul aria-label=\"Counter Size\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_pa_counter-size\" data-attribute_values='[\"120-x-80-x-60-mm\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-120-x-80-x-60-mm\" data-attribute_name=\"attribute_pa_counter-size\" data-title=\"120 x 80 x 60 mm\" data-value=\"120-x-80-x-60-mm\" data-wvstooltip=\"120 x 80 x 60 mm\" role=\"radio\" tabindex=\"0\" title=\"120 x 80 x 60 mm\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">120 x 80 x 60 mm</span></div></li></ul><a class=\"reset_variations\" href=\"#\">Clear</a> </td>\n</tr>\n</tbody>\n</table>",
"variations": {
"Counter Size": [
"120 x 80 x 60 mm"
]
},
"description": "Description\nA water-proof analog lightning strike counter is a universal type of lightning counter. When the lightning protection circuit system is functioning normally, there is no lightning current in the discharge line, and the lightning counter does not count. However, when a lightning current is discharged to the ground, the counter senses the current and performs lightning strike detection, accurately counting each strike by deflecting the numerical indicator.\nWhile analog in function, it complements modern systems with features often found in digital setups, though without requiring a digital display. This analog lightning strike counter is suitable for all lightning protection system applications. It counts accurately without the need for batteries or an external power source. The device is designed to be dust-proof and water-proof, ensuring durability and consistent performance even in harsh environments\nTECHNICAL PARAMETER\nT\nyp\ne\nWaterproof Lightning Strike Counter\nMinimum Counting Current(8/20ps)\n> 500 A\nCount Number\n0-999999 times\nDown Conductor Maximum Diameter\n6 to 12 mm\nMeasure (Height x Width x Depth)\n120 x 80 x 60 mm\nWorking Humidity\n< 95%\nOperating Temperature\n-40 ~+85° C\nCERTIFICATIONS\nCompliance to\nIEC 62561-6\nMAINTENANCE\nThe waterproof lightning counter doesn’t need special maintenance. Annually, check the down conductor bareness part of the lightning rod, to see whether the contact segment is well connected or not.",
"description_html": "<div aria-labelledby=\"tab-title-description\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--description panel entry-content wc-tab\" id=\"tab-description\" role=\"tabpanel\">\n<h2>Description</h2>\n<p>A water-proof analog lightning strike counter is a universal type of lightning counter. When the lightning protection circuit system is functioning normally, there is no lightning current in the discharge line, and the lightning counter does not count. However, when a lightning current is discharged to the ground, the counter senses the current and performs lightning strike detection, accurately counting each strike by deflecting the numerical indicator.<br/>\nWhile analog in function, it complements modern systems with features often found in digital setups, though without requiring a digital display. This analog lightning strike counter is suitable for all lightning protection system applications. It counts accurately without the need for batteries or an external power source. The device is designed to be dust-proof and water-proof, ensuring durability and consistent performance even in harsh environments<br/>\n<strong>TECHNICAL PARAMETER</strong></p>\n<table>\n<tbody>\n<tr>\n<td width=\"286\"><sup>T</sup>yp<sup>e</sup></td>\n<td width=\"304\">Waterproof Lightning Strike Counter</td>\n</tr>\n<tr>\n<td width=\"286\">Minimum Counting Current(8/20ps)</td>\n<td width=\"304\">> 500 A</td>\n</tr>\n<tr>\n<td width=\"286\">Count Number</td>\n<td width=\"304\">0-999999 times</td>\n</tr>\n<tr>\n<td width=\"286\">Down Conductor Maximum Diameter</td>\n<td width=\"304\">6 to 12 mm</td>\n</tr>\n<tr>\n<td width=\"286\">Measure (Height x Width x Depth)</td>\n<td width=\"304\">120 x 80 x 60 mm</td>\n</tr>\n<tr>\n<td width=\"286\">Working Humidity</td>\n<td width=\"304\">< 95%</td>\n</tr>\n<tr>\n<td width=\"286\">Operating Temperature</td>\n<td width=\"304\">-40 ~+85° C</td>\n</tr>\n</tbody>\n</table>\n<p><strong>CERTIFICATIONS</strong></p>\n<table>\n<tbody>\n<tr>\n<td width=\"295\">Compliance to</td>\n<td width=\"295\">IEC 62561-6</td>\n</tr>\n</tbody>\n</table>\n<p><strong>MAINTENANCE</strong><br/>\nThe waterproof lightning counter doesn’t need special maintenance. Annually, check the down conductor bareness part of the lightning rod, to see whether the contact segment is well connected or not.</p>\n</div>",
"technical_details": "CHARACTERISTICS\nMinimum threshold current rating\nlmin\n1 kA\nMaximum current rating\nImax\n100 kA\nProtection Class\nIP\n65\nBrand\n—\nAXIS\nOPERATING PRINCIPLES\nType\nAnalog\nDigits\n6\nImpulse Count\nUp to 999999\nPower Source\nNot require\nMounting\nWall-mounted and Pole mounted\nImpulse Waveform\n10/350 µs\nDown Conductor Fixing\nTerminal Connector (included)",
"technical_details_html": "<div aria-labelledby=\"tab-title-technical-details\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--technical-details panel entry-content wc-tab\" id=\"tab-technical-details\" role=\"tabpanel\">\n<table>\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"590\">\n<h5>CHARACTERISTICS</h5>\n</td>\n</tr>\n<tr>\n<td width=\"292\">Minimum threshold current rating</td>\n<td width=\"136\">lmin</td>\n<td width=\"162\">1 kA</td>\n</tr>\n<tr>\n<td width=\"292\">Maximum current rating</td>\n<td width=\"136\">Imax</td>\n<td width=\"162\">100 kA</td>\n</tr>\n<tr>\n<td width=\"292\">Protection Class</td>\n<td width=\"136\">IP</td>\n<td width=\"162\">65</td>\n</tr>\n<tr>\n<td width=\"292\">Brand</td>\n<td width=\"136\">—</td>\n<td width=\"162\">AXIS</td>\n</tr>\n</tbody>\n</table>\n<p> </p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"590\">\n<h5>OPERATING PRINCIPLES</h5>\n</td>\n</tr>\n<tr>\n<td width=\"292\">Type</td>\n<td width=\"298\">Analog</td>\n</tr>\n<tr>\n<td width=\"292\">Digits</td>\n<td width=\"298\">6</td>\n</tr>\n<tr>\n<td width=\"292\">Impulse Count</td>\n<td width=\"298\">Up to 999999</td>\n</tr>\n<tr>\n<td width=\"292\">Power Source</td>\n<td width=\"298\">Not require</td>\n</tr>\n<tr>\n<td width=\"292\">Mounting</td>\n<td width=\"298\">Wall-mounted and Pole mounted</td>\n</tr>\n<tr>\n<td width=\"292\">Impulse Waveform</td>\n<td width=\"298\">10/350 µs</td>\n</tr>\n<tr>\n<td width=\"292\">Down Conductor Fixing</td>\n<td width=\"298\">Terminal Connector (included)</td>\n</tr>\n</tbody>\n</table>\n</div>",
"how_to_install": "The Analog lightning counter can be installed with the down conductor suitable to mount on wall or mast. The installation diagram is as follows:\n1) Loosen the two screw nuts in the back of the lightning counter, remove the clamp, put the down conductor of the lightning rod between the two screw nuts, and then put the pressing plate and then screw nuts, tighten the two screw nuts.\n2) Pay attention to the down conductor of the lightning rod, the Installation and wiring diagram, the bareness part of the lightning rod and the mounting plate, and the pressing plate. The contact segment must be well connected to low down the contact resistance, to make sure counting accuracy).",
"how_to_install_html": "<div aria-labelledby=\"tab-title-how-to-install\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--how-to-install panel entry-content wc-tab\" id=\"tab-how-to-install\" role=\"tabpanel\">\n<p>The Analog lightning counter can be installed with the down conductor suitable to mount on wall or mast. The installation diagram is as follows:<br/>\n1) Loosen the two screw nuts in the back of the lightning counter, remove the clamp, put the down conductor of the lightning rod between the two screw nuts, and then put the pressing plate and then screw nuts, tighten the two screw nuts.<br/>\n<span class=\"Bodytext2\"><span lang=\"EN-US\" style=\"font-size: 12.0pt\">2) Pay attention to the down conductor of the lightning rod, the Installation and wiring diagram, the bareness part of the lightning rod and the mounting plate, and the pressing plate. The contact segment must be well connected to low down the contact resistance, to make sure counting accuracy).</span></span></p>\n</div>",
"image_url": "https://axis-india.com/wp-content/uploads/2023/08/Analog-Lightning-Counter.png",
"image_urls": [
"https://axis-india.com/wp-content/uploads/2023/08/Analog-Lightning-Counter.png"
]
}