Tension Clamp
✗ no variants.json found for this product
tension-clamp.json
{
"url": "https://axis-india.com/product/tension-clamp/",
"type": "product",
"breadcrumb": "Home > Lugs & Connectors > Aluminium Lugs & Connectors > Tension Clamp(Dead End Clamp)",
"breadcrumb_html": "<nav class=\"woocommerce-breadcrumb\"><a href=\"https://axis.espialsolutions.com/\">Home</a> > <a href=\"https://axis-india.com/product-category/lugs-connectors/\">Lugs & Connectors</a> > <a href=\"https://axis-india.com/product-category/lugs-connectors/aluminium-lugs/\">Aluminium Lugs & Connectors</a> > Tension Clamp(Dead End Clamp)</nav>",
"title": "Tension Clamp(Dead End Clamp)",
"title_html": "<h2 class=\"product_title entry-title\">Tension Clamp(Dead End Clamp)</h2>",
"product_meta": "Code: N/A",
"product_meta_html": "<div class=\"product_meta\">\n<span class=\"sku_wrapper\">Code: <span class=\"sku\">N/A</span></span>\n</div>",
"variations": {
"Conductor Range (mm2)": [
"35 - 80",
"100 - 150"
],
"Load (kN)": [
"15",
"20"
]
},
"variations_html": "<table cellspacing=\"0\" class=\"variations\" role=\"presentation\">\n<tbody>\n<tr>\n<th class=\"label\"><label for=\"conductor-range-mm2\">Conductor Range (mm2)</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_conductor-range-mm2\" data-show_option_none=\"yes\" id=\"conductor-range-mm2\" name=\"attribute_conductor-range-mm2\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"35 - 80\">35 - 80</option><option value=\"100 - 150\">100 - 150</option></select><ul aria-label=\"Conductor Range (mm2)\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_conductor-range-mm2\" data-attribute_values='[\"35 - 80\",\"100 - 150\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-35-80\" data-attribute_name=\"attribute_conductor-range-mm2\" data-title=\"35 - 80\" data-value=\"35 - 80\" data-wvstooltip=\"35 - 80\" role=\"radio\" tabindex=\"0\" title=\"35 - 80\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">35 - 80</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-100-150\" data-attribute_name=\"attribute_conductor-range-mm2\" data-title=\"100 - 150\" data-value=\"100 - 150\" data-wvstooltip=\"100 - 150\" role=\"radio\" tabindex=\"0\" title=\"100 - 150\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">100 - 150</span></div></li></ul> </td>\n</tr>\n<tr>\n<th class=\"label\"><label for=\"load-kn\">Load (kN)</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_load-kn\" data-show_option_none=\"yes\" id=\"load-kn\" name=\"attribute_load-kn\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"15\">15</option><option value=\"20\">20</option></select><ul aria-label=\"Load (kN)\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_load-kn\" data-attribute_values='[\"15\",\"20\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-15\" data-attribute_name=\"attribute_load-kn\" data-title=\"15\" data-value=\"15\" data-wvstooltip=\"15\" role=\"radio\" tabindex=\"0\" title=\"15\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">15</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-20\" data-attribute_name=\"attribute_load-kn\" data-title=\"20\" data-value=\"20\" data-wvstooltip=\"20\" role=\"radio\" tabindex=\"0\" title=\"20\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">20</span></div></li></ul><a class=\"reset_variations\" href=\"#\">Clear</a> </td>\n</tr>\n</tbody>\n</table>",
"description": "A Tension Clamp, also known as a dead-end clamp for a covered conductor system, is used to securely anchor and terminate covered conductors at the ends of a line or at points of directional change. It is designed to accommodate the required size of the covered conductor, considering its insulated outer layer, without compromising the insulation or structural integrity.\nTension Clamps (Dead-end clamps) ensure reliable mechanical and electrical performance under varying weather and load conditions. They provide a firm grip through self-adjustable wedges that distribute tension evenly while minimizing conductor damage. Additionally, these clamps are easy to install, highly durable, and comply with standard BS EN 50397-2, making them essential components in modern covered conductor systems for power distribution.\nThese dead end clamps are particularly useful in overhead distribution networks where maintaining conductor tension and alignment is critical for system reliability and safety. The robust design of a dead end clamp ensures long-term performance even in harsh environmental conditions, making it ideal for both urban and rural power infrastructure.”\nFeatures\nAnchors\ncovered conductors\nand applies tension to the line.\nSpecially designed plastic wedges firmly grip the conductor without damaging the insulation, ensuring long conductor life.\nDelivered ready-to-use, eliminating the need for assembly at the installation site.\nVoltage Range\n: 11kV to 33kV.\nTemperature Range\n: -20°C to 90°C.\nComplies with\nBS EN 50397-2\nstandard\nMaterial\nBody: Corrosion Resistant Aluminum Alloy\nWedges: UV Stabilized Engineering Plastic\nFAQ\nWhat is a dead end clamp used for in a covered conductor system?\nA dead end clamp is used to securely anchor and terminate covered conductors at the ends of a line or at points of directional change. It ensures reliable\nmechanical retention and electrical insulation\nunder varying weather and load conditions while preserving the conductor’s insulation.\nHow does the dead end clamp protect the conductor's insulation?\nThe clamp features specially designed UV-stabilized plastic wedges that grip the conductor firmly without damaging the insulation. This design distributes tension evenly, minimizing conductor\ninsulation\ndamage and extending its lifespan.\nWhat standards do Axis dead end clamps comply with?\nAxis dead end clamps comply with the BS EN 50397-2 standard, ensuring they meet international requirements for performance, safety, and durability in medium voltage (11kV–33kV) covered conductor systems.\nWhat are the key features of Axis dead end clamps?\nCorrosion-resistant aluminum alloy body for durability.\nReady-to-use design eliminates on-site assembly.\nWide temperature range of -20°C to 90°C for harsh outdoor environmental conditions.\nCustomizable for conductor sizes ranging from 35 mm² to 150 mm².",
"description_html": "<div aria-labelledby=\"tab-title-description\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--description panel entry-content wc-tab\" id=\"tab-description\" role=\"tabpanel\">\n<h2>Description</h2>\n<div class=\"elementor elementor-128488\" data-elementor-id=\"128488\" data-elementor-post-type=\"product\" data-elementor-type=\"product-post\">\n<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6ed30619 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-element_type=\"section\" data-id=\"6ed30619\">\n<div class=\"elementor-container elementor-column-gap-default\">\n<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7336d990\" data-element_type=\"column\" data-id=\"7336d990\">\n<div class=\"elementor-widget-wrap elementor-element-populated\">\n<div class=\"elementor-element elementor-element-da5b856 elementor-widget elementor-widget-text-editor\" data-element_type=\"widget\" data-id=\"da5b856\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\nA Tension Clamp, also known as a dead-end clamp for a covered conductor system, is used to securely anchor and terminate covered conductors at the ends of a line or at points of directional change. It is designed to accommodate the required size of the covered conductor, considering its insulated outer layer, without compromising the insulation or structural integrity.\nTension Clamps (Dead-end clamps) ensure reliable mechanical and electrical performance under varying weather and load conditions. They provide a firm grip through self-adjustable wedges that distribute tension evenly while minimizing conductor damage. Additionally, these clamps are easy to install, highly durable, and comply with standard BS EN 50397-2, making them essential components in modern covered conductor systems for power distribution.\nThese dead end clamps are particularly useful in overhead distribution networks where maintaining conductor tension and alignment is critical for system reliability and safety. The robust design of a dead end clamp ensures long-term performance even in harsh environmental conditions, making it ideal for both urban and rural power infrastructure.”\n<strong>Features </strong>\n<ul>\n<li>Anchors <a href=\"https://axis-india.com/covered-conductors-electrical-distribution/\">covered conductors</a> and applies tension to the line.</li>\n<li>Specially designed plastic wedges firmly grip the conductor without damaging the insulation, ensuring long conductor life.</li>\n<li>Delivered ready-to-use, eliminating the need for assembly at the installation site.</li>\n<li><strong>Voltage Range</strong>: 11kV to 33kV.</li>\n<li><strong>Temperature Range</strong>: -20°C to 90°C.</li>\n<li>Complies with <strong>BS EN 50397-2</strong> standard</li>\n</ul>\n<strong>Material </strong>\n<ul>\n<li>Body: Corrosion Resistant Aluminum Alloy</li>\n<li>Wedges: UV Stabilized Engineering Plastic</li>\n</ul> </div>\n</div>\n</div>\n</div>\n</div>\n</section>\n<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0faadd1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-element_type=\"section\" data-id=\"0faadd1\">\n<div class=\"elementor-container elementor-column-gap-default\">\n<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2087748\" data-element_type=\"column\" data-id=\"2087748\">\n<div class=\"elementor-widget-wrap elementor-element-populated\">\n<div class=\"elementor-element elementor-element-80ae595 elementor-widget elementor-widget-text-editor\" data-element_type=\"widget\" data-id=\"80ae595\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<h3>FAQ</h3> </div>\n</div>\n<div class=\"elementor-element elementor-element-a9ba041 elementor-widget elementor-widget-accordion\" data-element_type=\"widget\" data-id=\"a9ba041\" data-widget_type=\"accordion.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-accordion\">\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1771\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"1\" id=\"elementor-tab-title-1771\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\">What is a dead end clamp used for in a covered conductor system?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1771\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" id=\"elementor-tab-content-1771\" role=\"region\"><p>A dead end clamp is used to securely anchor and terminate covered conductors at the ends of a line or at points of directional change. It ensures reliable <span style=\"text-decoration: underline;\">mechanical retention and electrical insulation</span> under varying weather and load conditions while preserving the conductor’s insulation.</p></div>\n</div>\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1772\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"2\" id=\"elementor-tab-title-1772\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\">How does the dead end clamp protect the conductor's insulation?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1772\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" id=\"elementor-tab-content-1772\" role=\"region\"><p>The clamp features specially designed UV-stabilized plastic wedges that grip the conductor firmly without damaging the insulation. This design distributes tension evenly, minimizing conductor <span style=\"text-decoration: underline;\">insulation</span> damage and extending its lifespan.</p></div>\n</div>\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1773\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"3\" id=\"elementor-tab-title-1773\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\"> What standards do Axis dead end clamps comply with?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1773\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" id=\"elementor-tab-content-1773\" role=\"region\"><p>Axis dead end clamps comply with the BS EN 50397-2 standard, ensuring they meet international requirements for performance, safety, and durability in medium voltage (11kV–33kV) covered conductor systems.</p></div>\n</div>\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1774\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"4\" id=\"elementor-tab-title-1774\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\">What are the key features of Axis dead end clamps?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1774\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" id=\"elementor-tab-content-1774\" role=\"region\"><p>Corrosion-resistant aluminum alloy body for durability.</p><p>Ready-to-use design eliminates on-site assembly.</p><p>Wide temperature range of -20°C to 90°C for harsh outdoor environmental conditions.</p><p>Customizable for conductor sizes ranging from 35 mm² to 150 mm².</p></div>\n</div>\n</div>\n</div>\n</div>\n</div>\n</div>\n</div>\n</section>\n</div>\n</div>",
"technical_details": "",
"technical_details_html": "<div aria-labelledby=\"tab-title-technical-details\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--technical-details panel entry-content wc-tab\" id=\"tab-technical-details\" role=\"tabpanel\">\n<div class=\"elementor elementor-128488\" data-elementor-id=\"128488\" data-elementor-post-type=\"product\" data-elementor-type=\"product-post\">\n<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6ed30619 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-element_type=\"section\" data-id=\"6ed30619\">\n<div class=\"elementor-container elementor-column-gap-default\">\n<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7336d990\" data-element_type=\"column\" data-id=\"7336d990\">\n<div class=\"elementor-widget-wrap elementor-element-populated\">\n<div class=\"elementor-element elementor-element-da5b856 elementor-widget elementor-widget-text-editor\" data-element_type=\"widget\" data-id=\"da5b856\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\nA Tension Clamp, also known as a dead-end clamp for a covered conductor system, is used to securely anchor and terminate covered conductors at the ends of a line or at points of directional change. It is designed to accommodate the required size of the covered conductor, considering its insulated outer layer, without compromising the insulation or structural integrity.\nTension Clamps (Dead-end clamps) ensure reliable mechanical and electrical performance under varying weather and load conditions. They provide a firm grip through self-adjustable wedges that distribute tension evenly while minimizing conductor damage. Additionally, these clamps are easy to install, highly durable, and comply with standard BS EN 50397-2, making them essential components in modern covered conductor systems for power distribution.\nThese dead end clamps are particularly useful in overhead distribution networks where maintaining conductor tension and alignment is critical for system reliability and safety. The robust design of a dead end clamp ensures long-term performance even in harsh environmental conditions, making it ideal for both urban and rural power infrastructure.”\n<strong>Features </strong>\n<ul>\n<li>Anchors <a href=\"https://axis-india.com/covered-conductors-electrical-distribution/\">covered conductors</a> and applies tension to the line.</li>\n<li>Specially designed plastic wedges firmly grip the conductor without damaging the insulation, ensuring long conductor life.</li>\n<li>Delivered ready-to-use, eliminating the need for assembly at the installation site.</li>\n<li><strong>Voltage Range</strong>: 11kV to 33kV.</li>\n<li><strong>Temperature Range</strong>: -20°C to 90°C.</li>\n<li>Complies with <strong>BS EN 50397-2</strong> standard</li>\n</ul>\n<strong>Material </strong>\n<ul>\n<li>Body: Corrosion Resistant Aluminum Alloy</li>\n<li>Wedges: UV Stabilized Engineering Plastic</li>\n</ul> </div>\n</div>\n</div>\n</div>\n</div>\n</section>\n<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0faadd1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-element_type=\"section\" data-id=\"0faadd1\">\n<div class=\"elementor-container elementor-column-gap-default\">\n<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2087748\" data-element_type=\"column\" data-id=\"2087748\">\n<div class=\"elementor-widget-wrap elementor-element-populated\">\n<div class=\"elementor-element elementor-element-80ae595 elementor-widget elementor-widget-text-editor\" data-element_type=\"widget\" data-id=\"80ae595\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<h3>FAQ</h3> </div>\n</div>\n<div class=\"elementor-element elementor-element-a9ba041 elementor-widget elementor-widget-accordion\" data-element_type=\"widget\" data-id=\"a9ba041\" data-widget_type=\"accordion.default\">\n<div class=\"elementor-widget-container\">\n<div class=\"elementor-accordion\">\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1771\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"1\" id=\"elementor-tab-title-1771\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\">What is a dead end clamp used for in a covered conductor system?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1771\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" id=\"elementor-tab-content-1771\" role=\"region\"><p>A dead end clamp is used to securely anchor and terminate covered conductors at the ends of a line or at points of directional change. It ensures reliable <span style=\"text-decoration: underline;\">mechanical retention and electrical insulation</span> under varying weather and load conditions while preserving the conductor’s insulation.</p></div>\n</div>\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1772\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"2\" id=\"elementor-tab-title-1772\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\">How does the dead end clamp protect the conductor's insulation?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1772\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" id=\"elementor-tab-content-1772\" role=\"region\"><p>The clamp features specially designed UV-stabilized plastic wedges that grip the conductor firmly without damaging the insulation. This design distributes tension evenly, minimizing conductor <span style=\"text-decoration: underline;\">insulation</span> damage and extending its lifespan.</p></div>\n</div>\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1773\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"3\" id=\"elementor-tab-title-1773\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\"> What standards do Axis dead end clamps comply with?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1773\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" id=\"elementor-tab-content-1773\" role=\"region\"><p>Axis dead end clamps comply with the BS EN 50397-2 standard, ensuring they meet international requirements for performance, safety, and durability in medium voltage (11kV–33kV) covered conductor systems.</p></div>\n</div>\n<div class=\"elementor-accordion-item\">\n<div aria-controls=\"elementor-tab-content-1774\" aria-expanded=\"false\" class=\"elementor-tab-title\" data-tab=\"4\" id=\"elementor-tab-title-1774\" role=\"button\">\n<span aria-hidden=\"true\" class=\"elementor-accordion-icon elementor-accordion-icon-left\">\n<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"></i></span>\n<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"></i></span>\n</span>\n<a class=\"elementor-accordion-title\" tabindex=\"0\">What are the key features of Axis dead end clamps?</a>\n</div>\n<div aria-labelledby=\"elementor-tab-title-1774\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" id=\"elementor-tab-content-1774\" role=\"region\"><p>Corrosion-resistant aluminum alloy body for durability.</p><p>Ready-to-use design eliminates on-site assembly.</p><p>Wide temperature range of -20°C to 90°C for harsh outdoor environmental conditions.</p><p>Customizable for conductor sizes ranging from 35 mm² to 150 mm².</p></div>\n</div>\n</div>\n</div>\n</div>\n</div>\n</div>\n</div>\n</section>\n</div>\n</div>",
"image_urls": [
"https://axis-india.com/wp-content/uploads/2025/01/2-1.webp",
"https://axis-india.com/wp-content/uploads/2025/01/1-1.webp",
"https://axis-india.com/wp-content/uploads/2025/01/5-1.webp",
"https://axis-india.com/wp-content/uploads/2025/01/6-1.webp"
]
}