.. up

Stay Insulator

stay-insulator.jpg

stay-insulator-variants.json

Sr NoVoltage (KV)Creepage Distance (mm)Tensile Strength (KN)Flash Over Voltage DryFlash Over Voltage WetE Code
11.14853229ASI01
21157882713ASI11
333951104520ASI33

stay-insulator.json

{
  "url": "https://axis-india.com/product/stay-insulator/",
  "type": "product",
  "breadcrumb": "Home > > > Poleline Hardware > > > Insulators > > Stay Insulator",
  "breadcrumb_html": "<nav class=\"woocommerce-breadcrumb\"><a href=\"https://axis.espialsolutions.com/\">Home</a> &gt; <a href=\"https://axis-india.com/product-category/poleline-hardware/\">Poleline Hardware</a> &gt; <a href=\"https://axis-india.com/product-category/poleline-hardware/insulators/\">Insulators</a> &gt; Stay Insulator</nav>",
  "title": "Stay Insulator",
  "title_html": "<h2 class=\"product_title entry-title\">Stay Insulator</h2>",
  "product_meta": "Code: | N/A",
  "product_meta_html": "<div class=\"product_meta\">\n<span class=\"sku_wrapper\">Code: <span class=\"sku\">N/A</span></span>\n</div>",
  "variations_html": "<table cellspacing=\"0\" class=\"variations\" role=\"presentation\">\n<tbody>\n<tr>\n<th class=\"label\"><label for=\"voltage\">Voltage</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_voltage\" data-show_option_none=\"yes\" id=\"voltage\" name=\"attribute_voltage\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"1.1 KV\">1.1 KV</option><option value=\"11 KV\">11 KV</option><option value=\"33 KV\">33 KV</option></select><ul aria-label=\"Voltage\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_voltage\" data-attribute_values='[\"1.1 KV\",\"11 KV\",\"33 KV\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-1-1-kv\" data-attribute_name=\"attribute_voltage\" data-title=\"1.1 KV\" data-value=\"1.1 KV\" data-wvstooltip=\"1.1 KV\" role=\"radio\" tabindex=\"0\" title=\"1.1 KV\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">1.1 KV</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-11-kv\" data-attribute_name=\"attribute_voltage\" data-title=\"11 KV\" data-value=\"11 KV\" data-wvstooltip=\"11 KV\" role=\"radio\" tabindex=\"0\" title=\"11 KV\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">11 KV</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-33-kv\" data-attribute_name=\"attribute_voltage\" data-title=\"33 KV\" data-value=\"33 KV\" data-wvstooltip=\"33 KV\" role=\"radio\" tabindex=\"0\" title=\"33 KV\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">33 KV</span></div></li></ul> </td>\n</tr>\n<tr>\n<th class=\"label\"><label for=\"creepage-distance\">Creepage Distance</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_creepage-distance\" data-show_option_none=\"yes\" id=\"creepage-distance\" name=\"attribute_creepage-distance\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"48 mm\">48 mm</option><option value=\"57 mm\">57 mm</option><option value=\"95 mm\">95 mm</option></select><ul aria-label=\"Creepage Distance\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_creepage-distance\" data-attribute_values='[\"48 mm\",\"57 mm\",\"95 mm\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-48-mm\" data-attribute_name=\"attribute_creepage-distance\" data-title=\"48 mm\" data-value=\"48 mm\" data-wvstooltip=\"48 mm\" role=\"radio\" tabindex=\"0\" title=\"48 mm\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">48 mm</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-57-mm\" data-attribute_name=\"attribute_creepage-distance\" data-title=\"57 mm\" data-value=\"57 mm\" data-wvstooltip=\"57 mm\" role=\"radio\" tabindex=\"0\" title=\"57 mm\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">57 mm</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-95-mm\" data-attribute_name=\"attribute_creepage-distance\" data-title=\"95 mm\" data-value=\"95 mm\" data-wvstooltip=\"95 mm\" role=\"radio\" tabindex=\"0\" title=\"95 mm\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">95 mm</span></div></li></ul> </td>\n</tr>\n<tr>\n<th class=\"label\"><label for=\"tensile-strength\">Tensile Strength</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_tensile-strength\" data-show_option_none=\"yes\" id=\"tensile-strength\" name=\"attribute_tensile-strength\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"53 KN\">53 KN</option><option value=\"88 KN\">88 KN</option><option value=\"110 KN\">110 KN</option></select><ul aria-label=\"Tensile Strength\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_tensile-strength\" data-attribute_values='[\"53 KN\",\"88 KN\",\"110 KN\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-53-kn\" data-attribute_name=\"attribute_tensile-strength\" data-title=\"53 KN\" data-value=\"53 KN\" data-wvstooltip=\"53 KN\" role=\"radio\" tabindex=\"0\" title=\"53 KN\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">53 KN</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-88-kn\" data-attribute_name=\"attribute_tensile-strength\" data-title=\"88 KN\" data-value=\"88 KN\" data-wvstooltip=\"88 KN\" role=\"radio\" tabindex=\"0\" title=\"88 KN\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">88 KN</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-110-kn\" data-attribute_name=\"attribute_tensile-strength\" data-title=\"110 KN\" data-value=\"110 KN\" data-wvstooltip=\"110 KN\" role=\"radio\" tabindex=\"0\" title=\"110 KN\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">110 KN</span></div></li></ul> </td>\n</tr>\n<tr>\n<th class=\"label\"><label for=\"flash-over-voltage-kv-dry\">FLASH OVER VOLTAGE (KV) - Dry</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_flash-over-voltage-kv-dry\" data-show_option_none=\"yes\" id=\"flash-over-voltage-kv-dry\" name=\"attribute_flash-over-voltage-kv-dry\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"22\">22</option><option value=\"27\">27</option><option value=\"45\">45</option></select><ul aria-label=\"FLASH OVER VOLTAGE (KV) - Dry\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_flash-over-voltage-kv-dry\" data-attribute_values='[\"22\",\"27\",\"45\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-22\" data-attribute_name=\"attribute_flash-over-voltage-kv-dry\" data-title=\"22\" data-value=\"22\" data-wvstooltip=\"22\" role=\"radio\" tabindex=\"0\" title=\"22\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">22</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-27\" data-attribute_name=\"attribute_flash-over-voltage-kv-dry\" data-title=\"27\" data-value=\"27\" data-wvstooltip=\"27\" role=\"radio\" tabindex=\"0\" title=\"27\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">27</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-45\" data-attribute_name=\"attribute_flash-over-voltage-kv-dry\" data-title=\"45\" data-value=\"45\" data-wvstooltip=\"45\" role=\"radio\" tabindex=\"0\" title=\"45\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">45</span></div></li></ul> </td>\n</tr>\n<tr>\n<th class=\"label\"><label for=\"flash-over-voltage-kv-wet\">FLASH OVER VOLTAGE (KV) - Wet</label></th>\n<td class=\"value\">\n<select class=\"woo-variation-raw-select\" data-attribute_name=\"attribute_flash-over-voltage-kv-wet\" data-show_option_none=\"yes\" id=\"flash-over-voltage-kv-wet\" name=\"attribute_flash-over-voltage-kv-wet\" style=\"display:none\"><option value=\"\">Choose an option</option><option value=\"9\">9</option><option value=\"13\">13</option><option value=\"20\">20</option></select><ul aria-label=\"FLASH OVER VOLTAGE (KV) - Wet\" class=\"variable-items-wrapper button-variable-items-wrapper wvs-style-squared\" data-attribute_name=\"attribute_flash-over-voltage-kv-wet\" data-attribute_values='[\"9\",\"13\",\"20\"]' role=\"radiogroup\"><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-9\" data-attribute_name=\"attribute_flash-over-voltage-kv-wet\" data-title=\"9\" data-value=\"9\" data-wvstooltip=\"9\" role=\"radio\" tabindex=\"0\" title=\"9\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">9</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-13\" data-attribute_name=\"attribute_flash-over-voltage-kv-wet\" data-title=\"13\" data-value=\"13\" data-wvstooltip=\"13\" role=\"radio\" tabindex=\"0\" title=\"13\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">13</span></div></li><li aria-checked=\"false\" class=\"variable-item button-variable-item button-variable-item-20\" data-attribute_name=\"attribute_flash-over-voltage-kv-wet\" data-title=\"20\" data-value=\"20\" data-wvstooltip=\"20\" role=\"radio\" tabindex=\"0\" title=\"20\"><div class=\"variable-item-contents\"><span class=\"variable-item-span variable-item-span-button\">20</span></div></li></ul><a class=\"reset_variations\" href=\"#\">Clear</a> </td>\n</tr>\n</tbody>\n</table>",
  "variations": {
    "Voltage": [
      "1.1 KV",
      "11 KV",
      "33 KV"
    ],
    "Creepage Distance": [
      "48 mm",
      "57 mm",
      "95 mm"
    ],
    "Tensile Strength": [
      "53 KN",
      "88 KN",
      "110 KN"
    ],
    "FLASH OVER VOLTAGE (KV) - Dry": [
      "22",
      "27",
      "45"
    ],
    "FLASH OVER VOLTAGE (KV) - Wet": [
      "9",
      "13",
      "20"
    ]
  },
  "description": "Description\nStay insulator, also known as guy insulator, plays a crucial role in medium and low voltage lines. At Axis Electrical, we design and manufacture high-quality stay insulators that provide reliable insulation and mechanical support, ensuring the safety and efficiency of your power systems.\nWhat is a Stay Insulator?\nA stay insulator is a specific type of strain insulator used on stay wires, also referred to as guy wires. You typically install these insulators in the middle of a stay wire to provide essential insulation for utility poles and stay clamps. By preventing conductors from contacting the ground in the event of a wire break, stay insulators help you avoid potential hazards and electrical faults.\nStay insulators are essential for overhead transmission lines, particularly in scenarios where poles might fall or when stay wires face excessive mechanical loads that could lead to breakage.\nKey Features of Axis Electrical Stay Insulators\nHigh-Quality Materials:\nWe craft our stay insulators from premium porcelain, known for its excellent compressive strength and long-lasting durability. These insulators withstand the mechanical stresses and environmental conditions you encounter in the field.\nVoltage Specifications:\nWe offer stay insulators for different voltage levels, including 11kV and 33kV. These insulators are specifically optimized for use in overhead line networks, providing you with reliable insulation and mechanical support.\nEffective Insulation:\nStay-type insulators maintain electrical isolation between the stay wire and the ground. In case a pole breaks, the stay insulator keeps the lower portion of the conductor voltage-free, helping you prevent electrical faults and enhance safety.\nHow Does a Stay Insulator Work?\nA stay insulator features two holes positioned on opposite sides. You thread the stay wire through one hole and exit it through the other, creating a secure connection. If the pole or tower falls and pulls down the stay wires, the stay insulator ensures that the wires remain fully insulated, preventing any voltage from reaching the ground.\nApplications of Stay Type Insulators\nOverhead Transmission and Distribution Lines:\nStay insulators ensure the safety and integrity of your overhead lines, particularly in medium and low voltage applications.\nRural and Railway Networks:\nThese insulators provide essential insulation and support for power distribution in rural and railway networks.\nPole and Tower Safety:\nStay insulators play a critical role in maintaining proper insulation and preventing electrical faults when poles or towers are at risk of falling.\nChoose Axis Electrical’s stay insulators for your power transmission and distribution needs. We engineer our products to the highest standards, ensuring you receive reliable performance and safety in every application.",
  "description_html": "<div aria-labelledby=\"tab-title-description\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--description panel entry-content wc-tab\" id=\"tab-description\" role=\"tabpanel\">\n<h2>Description</h2>\n<p><strong> </strong>Stay insulator, also known as guy insulator, plays a crucial role in medium and low voltage lines. At Axis Electrical, we design and manufacture high-quality stay insulators that provide reliable insulation and mechanical support, ensuring the safety and efficiency of your power systems.</p>\n<h3>What is a Stay Insulator?</h3>\n<p>A stay insulator is a specific type of strain insulator used on stay wires, also referred to as guy wires. You typically install these insulators in the middle of a stay wire to provide essential insulation for utility poles and stay clamps. By preventing conductors from contacting the ground in the event of a wire break, stay insulators help you avoid potential hazards and electrical faults.</p>\n<p>Stay insulators are essential for overhead transmission lines, particularly in scenarios where poles might fall or when stay wires face excessive mechanical loads that could lead to breakage.</p>\n<h3>Key Features of Axis Electrical Stay Insulators</h3>\n<ul>\n<li><strong>High-Quality Materials:</strong> We craft our stay insulators from premium porcelain, known for its excellent compressive strength and long-lasting durability. These insulators withstand the mechanical stresses and environmental conditions you encounter in the field.</li>\n<li><strong>Voltage Specifications:</strong> We offer stay insulators for different voltage levels, including 11kV and 33kV. These insulators are specifically optimized for use in overhead line networks, providing you with reliable insulation and mechanical support.</li>\n<li><strong>Effective Insulation:</strong> Stay-type insulators maintain electrical isolation between the stay wire and the ground. In case a pole breaks, the stay insulator keeps the lower portion of the conductor voltage-free, helping you prevent electrical faults and enhance safety.</li>\n</ul>\n<h3>How Does a Stay Insulator Work?</h3>\n<p>A stay insulator features two holes positioned on opposite sides. You thread the stay wire through one hole and exit it through the other, creating a secure connection. If the pole or tower falls and pulls down the stay wires, the stay insulator ensures that the wires remain fully insulated, preventing any voltage from reaching the ground.</p>\n<h3>Applications of Stay Type Insulators</h3>\n<ul>\n<li><strong>Overhead Transmission and Distribution Lines:</strong> Stay insulators ensure the safety and integrity of your overhead lines, particularly in medium and low voltage applications.</li>\n<li><strong>Rural and Railway Networks:</strong> These insulators provide essential insulation and support for power distribution in rural and railway networks.</li>\n<li><strong>Pole and Tower Safety:</strong> Stay insulators play a critical role in maintaining proper insulation and preventing electrical faults when poles or towers are at risk of falling.</li>\n</ul>\n<p>Choose Axis Electrical’s stay insulators for your power transmission and distribution needs. We engineer our products to the highest standards, ensuring you receive reliable performance and safety in every application.</p>\n</div>",
  "technical_details": "Sr No\nVoltage (KV)\nCreepage Distance (mm)\nTensile Strength (KN)\nFlash Over Voltage\nE Code\nDry\nWet\n1\n1.1\n48\n53\n22\n9\nASI01\n2\n11\n57\n88\n27\n13\nASI11\n3\n33\n95\n110\n45\n20\nASI33",
  "technical_details_html": "<div aria-labelledby=\"tab-title-technical-details\" class=\"woocommerce-Tabs-panel woocommerce-Tabs-panel--technical-details panel entry-content wc-tab\" id=\"tab-technical-details\" role=\"tabpanel\">\n<table style=\"width: 100%\">\n<tbody>\n<tr>\n<th rowspan=\"2\">Sr No</th>\n<th rowspan=\"2\">Voltage (KV)</th>\n<th rowspan=\"2\">Creepage Distance (mm)</th>\n<th rowspan=\"2\">Tensile Strength (KN)</th>\n<th colspan=\"2\">Flash Over Voltage</th>\n<th rowspan=\"2\">E Code</th>\n</tr>\n<tr>\n<th>Dry</th>\n<th>Wet</th>\n</tr>\n<tr>\n<td>1</td>\n<td>1.1</td>\n<td>48</td>\n<td>53</td>\n<td>22</td>\n<td>9</td>\n<td>ASI01</td>\n</tr>\n<tr>\n<td>2</td>\n<td>11</td>\n<td>57</td>\n<td>88</td>\n<td>27</td>\n<td>13</td>\n<td>ASI11</td>\n</tr>\n<tr>\n<td>3</td>\n<td>33</td>\n<td>95</td>\n<td>110</td>\n<td>45</td>\n<td>20</td>\n<td>ASI33</td>\n</tr>\n</tbody>\n</table>\n</div>",
  "image_url": "https://axis-india.com/wp-content/uploads/2024/07/Stay-Insulator.jpg",
  "image_urls": [
    "https://axis-india.com/wp-content/uploads/2024/07/Stay-Insulator.jpg"
  ]
}